LK3U-32MR/MT-10AD-2DA

LK3U-32MR/MT-10AD-2DA
LK3U-32MR/MT-10AD-2DA
LK3U-32MR/MT-10AD-2DA
LK3U-32MR/MT-10AD-2DA
LK3U-32MR/MT-10AD-2DA
LK3U-32MR/MT-10AD-2DA
Hot -23 %
LK3U-32MR/MT-10AD-2DA
LK3U-32MR/MT-10AD-2DA
LK3U-32MR/MT-10AD-2DA
LK3U-32MR/MT-10AD-2DA
LK3U-32MR/MT-10AD-2DA
LK3U-32MR/MT-10AD-2DA
LK3U-32MR/MT-10AD-2DA
$89.00
$116.00
  • Stock: In Stock
  • Model: LK3U-32MR/MT-10AD-2DA
  • Weight: 0.70kg

Available Options

LK3U-32MR/MT-10AD-2DA 16 input 16 output plc controller RS485 RTC

LK3U-32MR4AD-2DA and LK3U-32MT4AD-2DA are both PLC (Programmable Logic Controller) units with 16 input and 16 output channels. The difference between the two is that the MR version has relay outputs while the MT version has transistor outputs.

The input channels are DC24V NPN type, and the MR version can handle AC250V/DC0V-DC30V load with a current of less than 3A, while the MT version can handle DC24V load with a current of less than 0.5A.

There are also high-speed pulse input and output channels, with 2 input channels capable of handling 60KHZ pulses, and 8 output channels capable of handling 200KHZ6 and 100KHZ2 pulses.

Additionally, there are 10 analog input channels with a default voltage range of 0-10V, and optional current or NTC temperature sensors with different temperature ranges. There are also 2 analog output channels that can output either 0-10V or 0-20MA.

The PLC units have communication ports, with 1 RS232 channel for program download and touch screen communication, and 2 RS485 channels for Modbus RTU/RS program download and touch screen communication.

Finally, there is an optional weighing function that can be added.


Model
LK3U-32MR4AD-2DA
LK3U-32MT4AD-2DA
Input Channels
16 DC24V NPN
16 DC24V NPN
Output Channels
16 relay outputs
16 transistor outputs
Relay Output Load
AC250V/DC0V-DC30V <3A-
Transistor Load
-
DC24V <0.5A (NPN output)
High-Speed Inputs
2 channels x0:60khz x1:10khz 
2 channels x0:60khz x1:10khz 
High-Speed Outputs

8 channels 200KHZ*6,100KHZ*2
Analog Inputs
10 channels (0-10V)
10 channels (0-10V)
Optional Current
0-20mA
0-20mA
Optional NTC Temp
NTC10K -40° ~150°,NTC50K -40° ~210°
NTC10K -40° ~150°,NTC50K -40° ~210°
Analog Outputs
2 channels (0-10V/0-20mA)
2 channels (0-10V/0-20mA)
Communication Ports
RS232, 2*RS485
RS232, 2*RS485
Optional Function
Weighing
Weighing

Supports one network interface

  • MELSOFT connection.
  • MODBUS S connection (MODBUS TCP (UDP) server).
  • SNTP connection.
  • MODBUS C connection (MODBUS TCP (UDP) client - UDP supports only one connection (supporting up to 247 slave devices), TCP supports seven connections (supporting up to 7 slave devices)).

Operating temperature

0℃~50 ℃

Storage temperature

20 ℃~60 ℃

Operating humidity

10%RH~90%RH( No condensation )

Air requirement 

No corrosion, no dust

working voltage

DC24V ± 10%

Working current

>1A

Program software

GX-Developer/GX-Works2

Maximum step

32000

Communication port1

RS232: program download, man-machine interface communication; programming port protocol, default baud rate 19200

Communication port2

RS485: man-machine interface communication, various instrument communication; default programming protocol, default baud rate 19200,

Communication port3

RS485: man-machine interface communication, various instrument communication; default programming protocol, default baud rate 19200,

Input 

DC24V NPN

Output 

Transistor:DC24V NPN(500mA);Relay:AC250V/DC30V;3A

AD

0-10V

DA

0-10V

More infomation https://www.lollette.com/plc-controller/lk3u-plc

PLC & HMI
Input Power DC 24V
Input 16
Output 16
Analog input 10*0-10V
Analog output 2*0-10V
Real Time Clock(RTC) support
RS485-Modbus 2*RS485
Certification CE